Electrical Technical Authority services
Electrical decisions can affect safety, reliability and the cost of operating your business. Our dedicated Technical Authority service gives you access to an experienced electrical consultant who offers technical electrical advice to help you identify risks and challenge assumptions before they become costly problems.
An Electrical Technical Authority can help support you with independent advice on electrical projects, operational issues and electrical safety arrangements. Early technical review can help you assess specifications, identify unnecessary scope and make informed engineering decisions. ESUK’s annual service gives your team access to specialist support within an agreed scope.
If your organisation needs additional senior electrical engineering expertise, our service can support your internal team.
FREE Electrical Safety Health Check
Providing Clarity on Compliance.
The Technical Authority helps you identify electrical risks, review the controls in place and decide where improvements are needed. The role provides technical advice and challenge within an agreed remit.
Our annual service offers support in defined areas or across a wider range of electrical engineering concerns. Your organisation retains its responsibilities for decisions, implementation and safe operation.
The service may be useful if you need additional expertise in any of the following areas:
- Relevant legal and technical requirements, including electrical safety, dangerous substances, work equipment, machinery and fire safety, within the agreed scope.
- Projects: engineering standards, design reviews and acceptance testing. Competence management: staff and supplier requirements, assessment, authorisation and auditing.
- Maintenance and asset management: preventive, predictive and condition-based approaches, obsolescence and ageing equipment.
- Electrical safety management: electric shock, arc flash, safety rules, electrical testing, isolation and work near electrical services or in hazardous areas.
- Technical evaluation of suppliers and advice to help you assess their proposals.
- Determining Electrical network reliability and the risk of losing supply.
For access to a Principal Consultant Engineering support for the technical issues that matter to your organisation. We agree the scope of the service with you and provide advice, reviews and assessments within the contracted allowance.
Contact us to discuss the service and confirm current pricing.
Annual service price: ÂŁ9,880.
Includes up to 50 hours of Principal Consultant Engineer support or consultancy over a 12-month period.
If the allowance is exhausted before the contract ends, additional support is charged at ÂŁ229 per hour for the remainder of that period.
General technical advice.
Meetings at your site, at ESUK’s offices or online, plus email and telephone support.
Document reviews.
Updates to policies, procedures and electrical safety rules.
Tender advice and support.
Technical design support.
Auditing.
Competence and authorisation assessments.
Travel time and expenses are converted into support hours and deducted from your remaining allowance. If the allowance has been exhausted, they are invoiced separately. Travel time and expenses are submitted on timesheets for your approval at ESUK’s standard rates.
ELECTRICAL SAFETY FAQs
Electrical safety management is the organised process of identifying, evaluating, and controlling electrical hazards in the workplace. It typically includes policies, electrical safety rules, procedures, competency management, inspections, maintenance, documentation, and ongoing program reviews.
A strong electrical safety management program helps protect workers, reduce the risk of shocks, arc flashes, fires, and equipment damage, and supports compliance with applicable workplace safety requirements.
Depending on the workplace, a program may include:
- Electrical safety policies and procedures
- Hazard identification and risk assessments
- Arc flash studies and equipment labelling
- Energised electrical work procedures
- Isolation processes
- Electrical equipment inspections
- Preventive maintenance
- Employee training and qualification management
- Personal protective equipment requirements
- Emergency response procedures
Audits, documentation, and corrective actionsÂ
Any organisation that owns, operates, maintains, or works around electrical equipment may benefit from an electrical safety management program. This includes manufacturing facilities, commercial buildings, construction sites, utilities, healthcare facilities, schools, data centers, and industrial operations.
An electrical hazard assessment identifies potential sources of electrical injury or damage and evaluates the likelihood and severity of those hazards. The results help determine appropriate controls, procedures, training, boundaries, and personal protective equipment.
Electrical safety focuses on preventing electrical incidents and injuries. Electrical safety management provides the framework for achieving that goal through consistent policies, assigned responsibilities, training, inspections, maintenance, documentation, and continual improvement.
Electrical safety is a shared responsibility. Management must provide resources, establish expectations, and enforce the program. Supervisors must plan and oversee safe work. Qualified workers must follow procedures and use appropriate controls. All employees should report hazards and unsafe conditions.
A competent worker has the training, knowledge, experience and skills to understand electrical equipment and recognise and avoid the hazards associated with the work being performed. Qualification requirements depend on the task, equipment, work environment, and applicable regulations or standards.
Employees who may be exposed to electrical hazards should receive training appropriate to their job responsibilities. Training may cover electrical hazard recognition, safe work practices, isolation, personal protective equipment, emergency procedures, and recognising the limits of their authorisation.
Electrical isolation is a procedure used to isolate hazardous energy sources and prevent equipment from being unexpectedly energised or started while servicing or maintenance is being performed. Effective procedures include shutdown, isolation, labelling, verification, removal of stored energy and controlled restoration of energy.
Energised work should generally be avoided whenever it is feasible to establish an electrically safe work condition. If energised work is necessary, it should be justified, planned, authorised, and performed by qualified workers using appropriate procedures, boundaries, tools, and protective equipment.
Preventive maintenance helps identify deterioration, loose connections, overheating, contamination, insulation damage, and other conditions that may increase the risk of electrical failure. A documented maintenance program can improve reliability and reduce hazards.
Inspection frequency depends on the equipment, operating environment, manufacturer recommendations, use, age, and risk level. However, light industrial or commercial facilities are typically inspected and tested every 5 years. Equipment should also be inspected after damage, modifications, abnormal operation, or an electrical incident.
An arc flash study evaluates the potential thermal energy released during an arc flash and helps determine required boundaries, equipment labels, protective equipment, and risk-reduction measures. It is one component of a broader electrical safety management program.
Labels provide workers with important hazard information, such as system voltage, arc flash boundary, incident energy, and required protective equipment. Labels must be accurate, legible, and updated when system conditions or equipment change.
Depending on the hazard, workers may need arc-rated clothing, safety glasses, face shields, voltage-rated gloves, hearing protection, hard hats, safety footwear, insulating blankets, and other protective equipment. PPE should be selected based on a documented hazard assessment.
Effective prevention measures include:
- De-energising and securing the equipment before work
- Using isolation procedures
- Restricting work to competent personnel
- Performing regular inspections and maintenance
- Keeping electrical rooms and work areas clear and secure
- Using properly rated tools and equipment
- Maintaining accurate electrical documentation
- Investigating incidents and near misses
- Correcting hazards promptly
- Conducting regular program audits
An electrical safety policy should define the organisation’s commitment to safety, roles and responsibilities, training requirements, safe work practices, energised work expectations, isolation requirements, PPE rules, incident reporting, inspections, maintenance, and program review.
Audits help determine whether policies and procedures are being followed and whether the program is effective. They can identify gaps in training, documentation, equipment condition, maintenance, labelling, and work practices before those gaps lead to an incident.
The program should be reviewed periodically and whenever there are significant changes to equipment, processes, personnel, facilities, regulations, or work practices. Reviews should also follow incidents, near misses, audit findings, or other indications that improvements are needed. Typical industrial and Commercial organisations review their program on an annual basis.
Yes. An electrical safety consultant can evaluate existing practices, identify gaps, perform hazard assessments, develop procedures, conduct training, support arc flash studies, review documentation, and help create a practical safety management program for your organisation.
Safety disclaimer: Electrical safety requirements vary by workplace, equipment, jurisdiction, and applicable regulations or standards. This information is for general education and does not replace a site-specific assessment, qualified professional advice, training, or applicable legal requirements.